In addition to the guarantee of capacity, the following performance figures can be provided in processing of clean Tenera FFB. From D x P of having of a minimum content of 80% wet pulp on fruit ripeness and harvested from mature trees. Other conditions are dependent on the quality of sterilization and digesting.
Oil Loss on Dry Basis Oil Contents on Dry Nuts Nut Breakage [ Based On Nuts ] [ Based on samples ] |
4 - 7% 0.8 - 1% 6 - 10 % 10 - 13 % |
We guarantee that all plant and machinery supplied shall be brand new of best quality and first class workmanship.
All the equipments are guaranteed for a period of 6 (six) months from date of commissioning or not later than 12 months from date of delivery. It covers the replacement free of charge, delivered to mill of all parts acknowledged to be defective.
The guarantee does not cover parts subject to normal wear and tear due to the lifetime, electricity and hydraulic components which are very sensitive to damage. Or overload running as if fruit stiffen overnight into the press cage or entering the harden articles like pieces of metal and the lack of lubricating oil to the gearbox etc.
Working Pressure | Oil Content on Dry % |
Nut breakage Based on Nut % |
35 kg/cm2 (500 psi) 50 kg/cm2 (700 psi) 70 kg/cm2 (1000 psi) 100 kg/cm2 (1500 psi) |
6 - 9 5 - 8 4 - 7 3 - 6 |
5 - 8 6 - 10 7 - 12 8 - 14 |
---|
Model | LP 4 - 6 | LP 10 -15 | ||
---|---|---|---|---|
Revolution (RPM) Working Pressure (kg/cm2) Dia. of Drive Pulley Capacity (Tons/FFB/Hour) Oil Loss On dry basis (%) Nut breakage based on nuts (%) Running Ampere |
10 - 11 50 - 70 8" 4 - 5 4 - 7 7 - 10 25 - 27A |
11 - 12 50 -70 9" 5 - 6 6 - 8 8 - 12 27 - 30A |
10 - 11 50 - 70 8" 11 - 12 4 - 7 7 - 10 35 - 38A |
11 - 12 50 - 70 9" 12 - 13 6 - 8 8 - 12 37 - 40A |
Model | LP 17M | LP 20 | ||
---|---|---|---|---|
Revolution (RPM) Working Pressure (kg/cm2) Dia. of Drive Pulley Capacity (Tons/FFB/Hour) Oil Loss On dry basis (%) Nut breakage based on nuts (%) Running Ampere |
10 - 11 50 - 70 8" 15 - 16 4 - 7 7 - 10 43 - 48A |
11 - 12 50 -70 9" 16 - 17 5 - 8 8 - 12 45 - 50A |
10 - 11 50 - 70 8" 20 - 21 4 - 7 7 - 10 60 - 67A |
11 - 12 50 - 70 9" 21 - 22 6 - 8 8 - 12 65 - 72A |